New Products
New Products
96 Fibers, MTP to MTP, 50um 10G OM4 Fiber, 12 Strands - MTP Backbone Trunk Cable
MTP is the high dense degree of optical fiber pre-connect system,which is generally use in three areas.
The Data Center application with high dense degree environment The optical fiber to the building The internal connector application in fiber equipment.
FiberZON's MTP fiber patch cable is compliant to IEC-61754-7 and TIA-604-5(FOCIS-5) standard. It can be widely used for10G upgrade to 40G/100G data center.
MTP Connector Types
MTP Male with Pins | MTP Female without Pins |
Two other clearly visible features are the noses and guide grooves (keys) on the top side.(Note: Female connector need to connect with male connector type.) |
Pre-terminated MTP Technology-Polarity
The three polarity methods A, B and C are used to guarantee the right bi-directional allocation.
Assembly Structure Illustration
The picture above is a 72 fibers trunk cable which is for your reference only.
MTP Trunk Fiber Patch Cables are terminated with MTP connector on both end.
1.The default diameter of the MTP cable is 3.0mm.
2.The default color of the single mode MTP connector is Blue.
3.The diameter of branch cable could be choose as 0.9mm,2.0mm,please kindly contact us at [email protected] for other diameter standard.
4.Due to Inventory was Changed frequently,96 fiber cable will be instead of by 8x12Fiber cable when the total order volume is less than 1000m.
5.FiberZON can also custom the pulling eyes, welcome to contact us if you need.
MTP&MPO Difference
The term MTP is a registered trademark of US Conec, it has been the main trend in European and American areas.
MTP/MPO Machinery & Testing Equipment
1 | Our adopt industry's leading high-performance polishing machine, and complemented by precision plates holders designed for MT ferrules. |
2 | The industry leading device of 3D interferometer provides verification of MTP/MPO polishing process, the interferometer making all parameters of hte polished MT ferrule complies and exceeds industry standards. |
3 | After the 3D interference detection, the flexibility of the tester provides the the complete spectrum of optical testing required for complex and high fiber count cable assemblies. |
Parameter Reference
Type | Single mode | Single mode | Multi mode | |||
(APC polish) | (PC polish) | (PC polish) | ||||
Fiber count | 8, 12, 24 etc. | 8, 12, 24 etc. | 8, 12, 24 etc. | |||
Fiber type | G652D, G657A1 etc. | G652D, G657A1 etc. | OM1, OM2, OM3 etc. | |||
Maximum Insertion Loss | Elite | Standard | Elite | Standard | Elite | Standard |
Low Loss | Low Loss | Low Loss | ||||
≤0.35 dB | ≤0.75 dB | ≤0.35 dB | ≤0.75 dB | ≤0.35dB | ≤0.60dB | |
Return Loss | ≥55 dB | ≥45 dB | ≥20 dB | |||
Durability | ≥200 times | ≥200 times | ≥200 times | |||
Operating Temperature | -10 ~ +70 | -10 ~ +70 | -10 ~ +70 | |||
Test Wavelength | 1310nm | 1310nm | 850nm |
Make To Order
Fiber Type | Cable Type | Fiber Count | Termination | Cable Length | Breakout Length (Inches) | Breakout Termination | Polarity | Lableing | |
OM4 OM3 OS1/2 OM2 OM1 | LSZH Bunch Riser Bunch LSZH Ribbon Riser Ribbon | 12 24 36 48 72 96 144 | First Connector MTP Female MTP Male APC MTP Female APC MTP Male | 1~999 | 12~99 (36" is typical) | 0.9mm (standard) 2.0mm 3.0mm | Style A Style B Style C | Standard Custom | |
Second Connector MTP Female MTP Male APC MTP Female APC MTP Male |